The Impact of Climate on the Efficiency and Performance of the Qayyarah Gas Station

https://doi.org/10.55529/jeimp.26.12.26

Authors

  • Obed Majeed Ali Renewable Energy Research Unit, Northern Technical University, 36001 Kirkuk, Iraq
  • Ahmed Nawfal Mustafa The Ministry of Electricity, the General Company for Northern Electric Power Production, Mosul, Iraq

Keywords:

Gas Turbine, Environment Temperature, Power Plant Performance, Thermal Efficiency, Specific Fuel Consumption.

Abstract

In this paper, we will attempt to study a fundamental problem, namely, how gas stations operate worse as the outside temperature rises and production decreases. This examination focused on the gas generator made at the Al-Qayyarah gas station. Based on the data from the station's fourth unit, it was discovered that the two factors that affect the compressor's theoretical efficiency, air temperature entering the device, and compression ratio, are strongly correlated. season is larger than summer because more concentrated energy is generated during the winter, reaching 107.5 MW, whilst concentrated energy production in the summer does not go over 85.8 MW, Due to the cold temperatures, efficiency in the winter was only 29%, while in the summer it was 27.2%.

Published

2022-11-08

How to Cite

Obed Majeed Ali, & Ahmed Nawfal Mustafa. (2022). The Impact of Climate on the Efficiency and Performance of the Qayyarah Gas Station. Journal of Environmental Impact and Management Policy, 2(06), 12–26. https://doi.org/10.55529/jeimp.26.12.26